Protecting transmitter PA stages from reflected power and inter-system intermod
A failed antenna, a wet feedline connector, or a strong nearby transmitter can drive reflected power back into the PA — and at multi-carrier sites, two transmitters mixing in a non-linear element generate intermod products that fall back into your receiver band.
The two failure modes
Reflected power: SWR climbs above 2:1 and the PA's reverse-power protection trips, or worse, fails open. A ferrite isolator absorbs reflected power into a load, decoupling the PA from antenna-side faults.
Inter-system intermod: when a strong second carrier reaches your transmitter's output stage, the non-linearity generates IM products that fall in-band at nearby receivers. The isolator presents > 75 dB of reverse isolation, suppressing the second carrier before it reaches your PA.
Recommended product
For UHF systems, uhf-isl-2-2. For VHF, vhf-isl-2-2. For airband, airb-isl-2-2. All three share the same dual-stage construction and temperature-stability curve — pick by band.
Need engineering review of your system?
Send us a system diagram or band plan and our application engineers will recommend a configuration.